2750/3150/3450kW PCS
- Wide DC bus voltage range
- All around the clock ground insulation monitoring, ensuring the safety of the system
- Intelligent wave recording and local touch screen monitoring, fast incident and fault positioning
- Flexible parallel connection and easy system expansion
- Grid forming function, alleviate transient voltage and frequency instability in the power system
- Smooth switch between Grid and Off-grid mode, "black start" function integrated
- Equipped with functions like VSG, PQ , VF, etc., support L/HVRT, FRT
- Support IEC 61850 protocol, rapid power response
Product Classification:
Centralized PCS
Key Words: Converter
Product Introduction
Type | HD06PCS2750 | HD07PCS3150 | HD08PCS3450 |
DC side Parameters | |||
Operating voltage range(V) | 800-1500 | 915-1500 | 1000-1500 |
Operating current range(A) | ≤2*1936 | ||
AC side Parameters | |||
AC rated power(kW) | 2750 | 3150 | 3450 |
Max.AC power(kW) | 3025 | 3465 | 3795 |
Max.AC current(A) | 2886A@45℃/3174A@30℃ | ||
Rated operating voltage(V) | 550 | 630 | 690 |
Permitted grid voltage deviation | -10~+10%(range adjustable) | ||
Rated operating frequency(Hz) | 50/60 | ||
Power factor adjustable range | -1~+1 | ||
Harmonic (THD) | <3%In | ||
Off-grid operating parameters | |||
Rated output voltage(V) | 550 | 630 | 690 |
Rated output frequency(Hz) | 50/60 | ||
Rated output power(kW) | 2750 | 3150 | 3450 |
Output voltage accuracy | <1%Un | ||
AC voltage distortion | <3%Un | ||
DC voltage component | <0.5%Un | ||
Common parameter | |||
Max.efficiency | 99% | ||
Operating temperature range(℃) | -35~+60,derating above 45℃ | ||
Operating humidity range | 0~95% | ||
Operating altitude(m) | ≤4000,derating above 2000m | ||
Cooling method | Intelligent air cooling | ||
Dimension(W*D*H)mm | (1050*1500*2377)*2 | ||
Degree of protection | IP55 | ||
Weight(kg) | 3000 | ||
Communication | RS485, CAN, Ethernet, 4G | ||
Standard | GB/T34120,GB/T34133 |
The control circuit of the converter separates the loop control circuit and the closed loop control circuit according to the control mode. The former is mainly used in some special equipment with low requirements; the latter has the function of automatic control and adjustment, and is widely used in various working machines.
According to the nature of the control signal, it is divided into analog control circuit and digital control circuit. Analog signal is the most commonly used DC voltage and current, easy to use the method of electricity to be processed and transformed; digital signal is a set of information parameters with discrete values of the discontinuous change of the signal. Digital control has high precision, but the circuit is more complex and expensive. Therefore, digital-analog hybrid control circuits are widely used in practice. In addition, the control circuit using the microcomputer also has many advantages.
Related Products
215/233kWh<br />C&I Energy Storage System
<ul> <li>High efficient single cluster management</li> <li>High efficient heat management technology extending system lifespan</li> <li>High quality cell in high consistency with cell health big data management</li> <li>Multi-stage protection, suitable for multi-scenario applications</li> <li>Modular design, high energy density, small footprint, easy for operation and maintainance</li> <li>Intelligent monitoring, fast fault positioning</li> <li>Multiple operation mode optional</li> <li>Flexible parallel connection and easy system expansion, eliminating DC circulating current and reducing parallel capacity loss</li> </ul>
<ul> <li>Wide DC bus voltage range</li> <li>Intelligent multi-grade fan speed regulation, no derating from -30℃to +50℃</li> <li>All around the clock ground insulation monitoring, ensuring the safety of thesystem</li> <li>Intelligent wave recording and local touch screen monitoring, fast incident and fault positioning</li> <li>Flexible parallel connection and easy system expansion</li> <li>Compatible with various batteries</li> <li>Smooth switch between Grid and Off-grid mode, "black start" function integrated</li> <li>Equipped with functions like VSG, PQ , VF, etc., support L/HVRT, FRT</li> </ul>
2750/3150/3450kW Converter Booster Integrated Machine
<ul> <li>Wide DC bus voltage range</li> <li>All around the clock ground insulation monitoring, ensuring the safety of the system</li> <li>Intelligent wave recording and local touch screen monitoring, fast incident and fault positioning</li> <li>Flexible configuration of voltage class, circuit breaker, etc.</li> <li>Grid forming function, alleviate transient voltage and frequency instability in the power system</li> <li>IP 55 protection on the entire body, suitable for various harsh environments</li> <li>Support IEC 61850 protocol, rapid power response</li> </ul>
Immediate Consultation
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!