Products


+
  • 未标题-6.png

100kW Built-in PCS


  • Wide DC bus voltage range
  • Advanced three-level technology, max efficiency 98.3%
  • All around the clock ground insulation monitoring, ensuring the safety of the system
  • Intelligent wave recording, fast incident and fault positioning
  • Flexible parallel connection and easy system expansion
  • Equipped with functions like VSG, PQ , VF, etc., support L/HVRT, FRT

Product Classification:

String PCS

Key Words: Converter

Online Message

Product Introduction

Type HD03PCS0100
DC side Parameters
Operating voltage range(V) 580-950
Operating current range(A)    ≤194
AC side Parameters
AC rated power(kW)      100
Max.AC power(kW) 110
Rated operating voltage(V) 380/400
AC side connection Three-phase three-wire/Three-phase four-wire
Permitted grid voltage deviation 15~+10%(range adjustable)
Rated operating frequency(Hz) 50/60
Grid frequency range(Hz) 50/60±5%
Power factor adjustable range -1~+1
Harmonic (THD) <3%In
Off-grid operating parameters
Rated output voltage(V)  380/400
Rated output frequency(Hz) 50/60
Rated output power(kW) 100
Output voltage accuracy <1%Un
AC voltage distortion <3%Un
DC voltage component <0.5%ln
System parameters
Max.efficiency 98.3%
Operating temperature range(℃) -35~+60, derating above 45℃
Operating humidity range 0~85%,non-condensing
Operating altitude(m) ≤4000,derating by 1% with each 100m increase for altitude above 2000m
Cooling methed Intelligent air cooling
Dimension(W*D*H)mm 440*720*215(excl. hangers)
Degree of protection IP20
Noise level(dB) <80
Weight(kg) <60
Communication RS485, CAN, Ethernet, 4G
Standard GB/T34120-2023

The control circuit of the converter separates the loop control circuit and the closed loop control circuit according to the control mode. The former is mainly used in some special equipment with low requirements; the latter has the function of automatic control and adjustment, and is widely used in various working machines.
According to the nature of the control signal, it is divided into analog control circuit and digital control circuit. Analog signal is the most commonly used DC voltage and current, easy to use the method of electricity to be processed and transformed; digital signal is a set of information parameters with discrete values of the discontinuous change of the signal. Digital control has high precision, but the circuit is more complex and expensive. Therefore, digital-analog hybrid control circuits are widely used in practice. In addition, the control circuit using the microcomputer also has many advantages.

Related Products

215/233kWh<br />C&I Energy Storage System

<ul> <li>High efficient single cluster management</li> <li>High efficient heat management technology extending system lifespan</li> <li>High quality cell in high consistency with cell health big data management</li> <li>Multi-stage protection, suitable for multi-scenario applications</li> <li>Modular design, high energy density, small footprint, easy for operation and maintainance</li> <li>Intelligent monitoring, fast fault positioning</li> <li>Multiple operation mode optional</li> <li>Flexible parallel connection and easy system expansion, eliminating DC circulating current and reducing parallel capacity loss</li> </ul>

630kW Centralized PCS

<ul> <li>Wide DC bus voltage range</li> <li>Intelligent multi-grade fan speed regulation, no derating from -30℃to +50℃</li> <li>All around the clock ground insulation monitoring, ensuring the safety of thesystem</li> <li>Intelligent wave recording and local touch screen monitoring, fast incident and fault positioning</li> <li>Flexible parallel connection and easy system expansion</li> <li>Compatible with various batteries</li> <li>Smooth switch between Grid and Off-grid mode, "black start" function integrated</li> <li>Equipped with functions like VSG, PQ , VF, etc., support L/HVRT, FRT</li> </ul>

2750/3150/3450kW Converter Booster Integrated Machine

<ul> <li>Wide DC bus voltage range</li> <li>All around the clock ground insulation monitoring, ensuring the safety of the system</li> <li>Intelligent wave recording and local touch screen monitoring, fast incident and fault positioning</li> <li>Flexible configuration of voltage class, circuit breaker, etc.</li> <li>Grid forming function, alleviate transient voltage and frequency instability in the power system</li> <li>IP 55 protection on the entire body, suitable for various harsh environments</li> <li>Support IEC 61850 protocol, rapid power response</li> </ul>

Immediate Consultation

If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!

Submit Message